I/O Relay
last update: May 22, 2023
| Rated voltage (V) | Rated current | Coil
resistance |
Must operate
voltage |
Must release
voltage |
Max.
voltage |
Power
consumption |
||
|---|---|---|---|---|---|---|---|---|
| 50 Hz | 60 Hz | |||||||
| AC | 100/110 | 8.2/9 mA | 7/7.7 mA | 8,700 Ω | 80% max. of
rated value |
30% min. of
rated value |
110% of
rated value |
0.7 VA |
| 200/220 | 4.1/4.5 mA | 3.5/3.85 mA | 33,300 Ω | |||||
| DC | 12 | 42 mA | 290 Ω | 80% max. of
rated value |
10% min. of
rated value |
110% of
rated value |
0.5 W | |
| 24 | 21 mA | 1,150 Ω | ||||||
| 100/110 | 5 mA | 20,000 Ω | 80% max. of
rated value |
10% min. of
rated value |
110% of
rated value |
0.5 W | ||
| Classification | For input | For output | ||
|---|---|---|---|---|
| Resistive load
(cosφ = 1) |
Inductive load
(L/R = 7 ms) |
Resistive load
(cosφ = 1) |
Inductive load
(cosφ = 0.4, L/R = 7 ms) |
|
| Contact mechanism | Crossbar bifurcated | Single | ||
| Contact material | Au-clad Ag | AgSnIn | ||
| Rated load | 1 A at 24 VDC | 0.5 A at 24 VDC | 5 A at 24 VDC
2 A at 220 VAC |
2 A at 24 VDC
1 A at 220 VAC |
| Rated carry current | 1 A | 5 A | ||
| Max. switching voltage | 250 VAC, 125 VDC | |||
| Max. switching current | 1 A | 5 A | ||
| Failure rate (reference value) | 100 μA at 1 VDC | 10 mA at 5 VDC | ||
| Contact resistance (see note 2) | 50 mΩ max. |
|---|---|
| Operate time (see note 3) | 15 ms max. |
| Release time (see note 3) | 15 ms max. |
| Max. operating frequency | Mechanical: 18,000 operations/hour
Electrical: 1,800 operations/hour (under rated load) |
| Insulation resistance (see note 4) | 100 MΩ (at 500 VDC) |
| Dielectric strength | Between coil and contacts: 2,000 VAC, 50/60 Hz for 1 minute
Between contacts of same polarity: 1,000 VAC, 50/60 Hz for 1 minute |
| Vibration resistance | Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double
amplitude) |
| Shock resistance | Malfunction: 200 m/s2 |
| Mechanical endurance | 50,000,000 operations |
| Electrical endurance (see note 5) | Input:10,000,000 operations (10 mA) or 50,000 operations (1 A) with resistive load
2,500,000 operations (10 mA) or 20,000 operations (0.5 A) with inductive load Output:1,000,000 operations with rated load |
| Error rate (level P) (Reference
value) (see note 6) |
Input: 100 μA at 1 VDC
Output: 10 mA at 5 VDC |
| Ambient temperature | Operating: -40°C to 70°C (with no icing or condensation) |
| Ambient humidity | Operating: 5% to 85% (with no icing or condensation) |
| Weight | Approx. 17 g |
| Model | P7TF-05 |
|---|---|
| Contact resistance | 10 mΩ max. |
| Dielectric strength | 2,000 VAC for 1 minute |
| Insulation resistance | 1,000 MΩ min. (at 500 VDC) |
| Vibration resistance | 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) |
| Shock resistance | 1,000 m/s2 |
| Ambient temperature | Operating:-40°C to 70°C (with no icing or condensation) |
| Ambient Humidity | Operating: 5% to 85%RH |
| Weight | Approx. 28 g |
* Measurement condition: 1 A at 5 VDC.
last update: May 22, 2023