E5Z Series Digital Controllers:

 

 Item               Model

E5CZ

E5EZ

E5AZ

E5EZ-PRR

Appearance

E5CZ

E5EZ

E5AZ

E5EZ-PPR

No. of loops

1

Size

48 × 48 mm (front mount)

48 × 96 mm (front mount)

96 × 96 mm (front mount)

48 × 96 mm (front mount)

Input accuracy

±0.5%

Input type

Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100; Infrared temperature sensor;

Voltage input: 0 to 50 mV

Input impedance

Current input: 150 Ω, Voltage input: 1 MΩ

Sampling rate

250 ms

Power supply

Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or 24 VDC

Universal AC Power (100 to 240 VAC, 50/60 Hz)

Operating power

85% to 110% of rated supply voltage

Power consumption

100 to 240 VAC: 7.5 VA max.
24 VAC: 5.5 VA max.
24 VDC: 3.5 W max.

100 to 240 VAC: 8.5 VA max.
24 VAC: 6 VA max.
24 VDC: 4 W max.

10 VA (10W)

Control type

ON/OFF or 2 PID control (with auto-tuning)

2 PID control (with autotuning)

Control mode

Heating/cooling control

Position proportional control only

Control output

Relay output: SPST; SSR driver (voltage); Current output

Relay output: 2 nos of relays (SPST), for open and close function

Auxiliary output

Not supported

Event output

2 max.

Logic operation

Not supported

Transfer output

Not supported

Remote setpoint

Not supported

Potentiometer

Not supported

100 to 2500 Ω

Heater / SSR failure detection

Heater detection (1 CT only)

Not supported

Setting method

Digital setting using front panel key or software access

Indication method

11-segment 2-line digital and individual indicator

7-segment 3-line digital and single lighting indicator

Setpoint program

Not supported

Bank switching

Not supported

Communication type

RS-485 communication type, supporting Compoway/F or Modbus

RS-232 or RS-485 communication type, supporting Compoway/F or Modbus

Alarm

2 alarms

3 alarms

2 alarms

Configuration software

USB-Serial conversion cable with Thermo Mini software

 

 

E5N Series Digital Controllers:

 

 Item             Model

E5GN

E5CN

E5EN

E5AN

Appearance

E5GN

E5CN

E5EN

E5AN

No. of loops

1

Size

48 × 24 mm (panel mount)

48 × 48 mm (front mount)

48 × 96 mm (front mount)

96 × 96 mm (front mount)

Input accuracy

Thermocouple: ±0.3%; Pt/analog: ±0.2%

Input type

Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100;
Infrared temperature sensor; Voltage input: 0 to 50 mV

Input impedance

Current input: 150 Ω, Voltage input: 1 MΩ

Sampling rate

250 ms

Power supply

Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or 24 VDC

Operating power

85% to 110% of rated supply voltage

Power consumption

100 to 240 VAC: 5.5 VA max.
24 VAC: 3 VA max.
24 VDC: 2 W max.

100 to 240 VAC: 7.5 VA max.
24 VAC: 5 VA max.

24 VDC: 3 W max.

100 to 240 VAC: 10 VA max.
24 VAC: 5.5 VA max.

24 VDC: 4 W max.

Control type

ON/OFF or 2 PID control (with auto-tuning)

Control mode

Standard or heating/cooling control

Control output

Relay output: SPST; SSR driver (voltage); Current output

Auxiliary output

2 max. 3 max.

Event output

2 max.

Logic operation

8 operations

Transfer output

Supported on control OUT1

Remote setpoint

Not supported

Potentiometer

Not supported

Heater / SSR failure detection

1 CT input for heater and SSR failure detection

2 CT inputs for heater and SSR failure detection

Setting method

Digital setting using front panel key or software access

Indication method

11-segment 1-line digital and single lighting indicator

11-segment 2-line digital and individual indicator 11-segment 3-line digital and individual indicator

Setpoint program

Not supported

Bank switching

Not supported

Communication type

RS-232 or RS-485 communication type, supporting Compoway/F or Modbus

Alarm

2 alarms

Configuration software

USB-Serial conversion cable with CX-Thermo software

 

E5N Series Advanced Digital Controllers:

 

 Item               Model

E5CN-H

E5EN-H

E5AN-H

Appearance

E5CN-H

E5EN-H

E5AN-H

No. of loops

1

Size

48 × 48 mm (front mount)

48 × 96 mm (front mount)

96 × 96 mm (front mount)

Input accuracy

±0.1%

Input type

Fully universal inputs can be selected from Thermocouple, RTD, VDC, or mA

Input impedance

Current input: 150 Ω, Voltage input: 1 MΩ

Sampling rate

60 ms

Power supply

Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or 24 VDC

Operating power

85% to 110% of rated supply voltage

Power consumption

100 to 240 VAC: 8.5 VA max.
24 VAC: 5.5 VA max.
24 VDC: 3.5 W max.

100 to 240 VAC: 12 VA max.
24 VAC: 8.5 VA max.
24 VDC: 5.5 W max.

Control type

ON/OFF or 2 PID control (with auto-tuning)

Control mode

Standard or heating/cooling control

Standard, heating/cooling or position proportional control

Control output

Relay output: SPST; SSR driver (voltage); Current output

Auxiliary output

2 max.

3 max.

Event output

2 max.

4 max.

Logic operation

8 operations

Transfer output

Supported

Remote setpoint

Not supported

Supported

Potentiometer

Not supported

Supported

Heater / SSR failure detection

2 CT inputs for heater and SSR failure detection

Setting method

Digital setting using front panel key or software access

Indication  method

11-segment 2-line digital and individual indicator, with 5-digit display

11-segment 3-line digital and individual indicator, with 5-digit display

Setpoint program

1 × 8 segment (bank switching)

Bank switching

8 banks

Communication type

RS-232 or RS-485 communication type, supporting Compoway/F, Sysway or Modbus

Alarm

2 alarms

3 alarms

Configuration software

USB-Serial conversion cable with CX-Thermo software

 

 

E5R Series High-performance Controllers:

 

 Item             Model

E5ER

E5AR

E5ER-T

E5AR-T

Appearance

E5EN

E5AN

E5EN

E5AN

No. of loops

2

4

2

4

Size

48 × 96 mm (front mount)

96 × 96 mm (front mount)

48 × 96 mm (front mount)

96 × 96 mm (front mount)

Input accuracy

±0.1%

Input type

Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100;
Current Input: 4 to 20 mA DC, 0 to 20 mA DC; Voltage input: 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC

Input impedance

Current input: 150 Ω, Voltage input: 1 MΩ

Sampling rate

50 ms

Power supply

Universal AC Power (100 to 240 VAC, 50/60 Hz), 24 VAC, 50/60 Hz or 24 VDC

Operating power

85% to 110% of rated supply voltage

Power consumption

100 to 240 VAC: 17 VA
24 VAC/VDC: 11 VA/7 W

100 to 240 VAC: 22 VA
24 VAC/VDC: 15 VA/10 W

100 to 240 VAC: 17 VA
24 VAC/VDC: 11 VA/7 W

100 to 240 VAC: 22 VA
24 VAC/VDC: 15 VA/10 W

Control type

2 PID control (with auto-tuning)

Control mode

Standard, heating/cooling or position-proportional control

Control output

Relay output: SPST; SSR driver (voltage); Current output

Auxiliary output

4 max.

Event output

6 max.

Logic operation

Math functions

Transfer output

Supported

Remote setpoint

Supported

Potentiometer

Supported

Heater / SSR failure detection

Not supported

Setting method

Digital setting using front panel key or software access

Indication method

7-segment 3-line digital and single lighting indicator

Setpoint program

1 × 8 segments (bank switching)

32 programs × 256 segments

Bank switching

8 banks

Communication type

RS-485 communication type, supporting Compoway/F, Modbus and DeviceNet

Alarm

No boundary

Configuration software

CX-Thermo through RS-485 terminal

 

Multi-loop Modular Controllers:

 

 Item         Model

EJ1

E5ZN

E5ZN-DRT

Appearance

EJ1

E5ZN

E5ZN-DRT

No. of loops

4/module

2/module

DeviceNet module

Size

HFU: 31 × 95.4 mm;

End Unit: 15.7 × 95.4 mm (In-Panel DIN Rail)

Each module: 130 × 30 mm (In-Panel DIN Rail)

---

Input accuracy

±0.5%

---

Input type

Fully universal inputs can be selected from Thermocouple, RTD, VDC or mA

Thermocouple K, J, L, T, E, U, N, R, S or B; RTD Pt-100, JPt-100;
Infrared temperature sensor; Voltage input: 0 to 50 mV

Input impedance

Current input: 150 Ω, Voltage input: 1 MΩ

---

Sampling rate

250 ms

500 ms ---

Power supply

24 VDC

Operating power

85% to 110% of rated supply voltage

Power consumption

5 W

3 W

Control type

ON/OFF or 2 PID control

---

Control mode

Standard or heating/cooling control

---

Control output

SSR driver, Transistor, Current output

---

Auxiliary output

Supported

---

Event output

Supported

---

Logic operation

Supported

Not supported

---

Transfer output

Supported

---

Remote setpoint

Not supported

---

Potentiometer

Not supported

---

Heater / SSR failure detection

Not supported

Heater burnout alarm ---

Setting method

Setting through software

By setting display unit ---

Indication  method

Not supported

---

Setpoint program

Not supported

---

Bank switching

8 banks

Not supported

---

Communication type

RS-422, RS-485, RS-232, Devicenet, supporting Compoway/F or Modbus

RS-485 communication type,
supporting Modbus

DeviceNet

Alarm

No boundary

---

Configuration software

USB-Serial Conversion cable with
CX-Thermo software

---

 

Other Controllers:

 

 Item               Model

E5C2

E5CS / E5CSV

Appearance

E5C2

E5CS

No. of loops

1

Size

48 × 48 mm (front mount)

Input accuracy

±2%

±0.5%

Input type

Thermocouple J or K, RTD Pt-100 and Thermistor THE

Thermocouple K, J, L, T, U, N or R, RTD Pt-100, JPt-
100, Thermistor: E52-THE

Input impedance

---

Sampling rate

---

500 ms

Power supply

100/110/120 VAC or 200/220/240 VAC

Universal AC Power (100 to 240 VAC, 50/60 Hz)

24 VAC/VDC

Operating power

90% to 110% of rated supply voltage

85% to 110% of rated supply voltage

Power consumption

Approx. 2 VA

100 to 240 VAC: 5 VA

24 VAC/VDC: 3 VA/2 W

Control type

ON/OFF or position-proportional control

ON/OFF or 2 PID control (with automatic PID setting)

Control mode

Standard

Control output

Relay output: SPST

Relay output: SPST; SSR driver (voltage)

Auxiliary output

Not supported

Event output

Not supported

Logic operation

Not supported

Transfer output

Not supported

Remote setpoint

Not supported

Potentiometer

Not supported

Heater / SSR failure detection

Not supported

Setting method

Analog setting

Digital setting using front panel key and DIP switch setting

Indication method

No indication

7-segment single-line digital and deviation indicator

Setpoint program

Not supported

Bank switching

Not supported

Communication type

Not supported

Alarm

Not supported

2 alarms

Configuration software

Not supported