Digital Controller
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 15, 2016
Size | Control
type |
Control mode | Outputs
(control/ transfer) |
Optional functions | Model | ||
---|---|---|---|---|---|---|---|
Auxiliary
outputs (SUB) |
Event
inputs |
Serial
com- muni- cations |
|||||
96
× 96 mm |
Basic
control (1 loop) |
Single-loop standard
control Single-loop heating and cooling control |
2 points: Pulse
voltage and Pulse voltage/current |
4 | 2 | No | E5AR-Q4B |
2 points: Current
and Current |
E5AR-C4B | ||||||
2 points: Pulse
voltage and Pulse voltage/current |
RS-485 | E5AR-Q43B-FLK | |||||
2 points: Current
and Current |
E5AR-C43B-FLK | ||||||
2 points: Pulse
voltage and Pulse voltage/current |
6 | E5AR-Q43DB-FLK | |||||
2 points: Current
and Current |
E5AR-C43DB-FLK | ||||||
4 points: Pulse
voltage and Pulse voltage/current and Current (2 points) |
E5AR-QC43DB-FLK | ||||||
2-loop
control |
2-loop standard control
Single-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control |
2 points: Pulse
voltage and Pulse voltage/current |
4 | 4 | RS-485 | E5AR-Q43DW-FLK | |
2 points: Current
and Current |
E5AR-C43DW-FLK | ||||||
2-loop standard control
2-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control |
4 points: Pulse
voltage (2 points) and Pulse voltage/ current (2 points) |
E5AR-QQ43DW-FLK | |||||
4-loop
control |
4-loop standard control
2-loop heating and cooling control |
4 points: Current
output (4 points) |
4 | 4 | RS-485 | E5AR-CC43DWW-FLK | |
4 points: Pulse
voltage (2 points) and Pulse voltage/ current (2 points) |
E5AR-QQ43DWW-FLK | ||||||
Position-
pro- portional control (1 loop) |
4-loop standard control
2-loop heating and cooling control |
Relay output
(1 open, 1 close) |
4 | 4 | No | E5AR-PR4DF | |
Relay output
(1 open, 1 close) and 1 current (transfer) output |
RS-485 | E5AR-PRQ43DF-FLK |
Note: Can be switched between close control and floating control.
Size | Control
type |
Control mode | Outputs
(control/ transfer) |
Optional functions | Model | ||
---|---|---|---|---|---|---|---|
Auxiliary
outputs (SUB) |
Event
inputs |
Serial
com- muni- cations |
|||||
96
× 96 mm |
Basic
control (1 loop) |
Single-loop standard
control Single-loop heating and cooling control |
2 points: Pulse voltage
and Pulse voltage/ current |
4 | 2 | No | E5AR-Q4B |
2 points: Current and
Current |
E5AR-C4B | ||||||
4 points: Pulse voltage
and Pulse voltage/ current and Current (2 points) |
6 | RS-485 | E5AR-QC43DB-FLK | ||||
2-loop
control |
2-loop standard
control 2-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control |
4 points: Pulse voltage
(2 points) and Pulse voltage/current (2 points) |
4 | 4 | RS-485 | E5AR-QQ43DW-FLK | |
4-loop
control |
4-loop standard
control 2-loop heating and cooling control |
4 points: Current
output (4 points) |
4 | 4 | RS-485 | E5AR-CC43DWW-FLK | |
Position-
pro- portional control (1 loop) |
Single-loop position-
proportional control (See note.) |
Relay output
(1 open, 1 close) |
4 | 4 | No | E5AR-PR4DF | |
Relay output
(1 open, 1 close) and 1 current (transfer) output |
RS-485 | E5AR-PRQ43DF-FLK |
Note: Can be switched between close control and floating control.
Size | Control
type |
Control mode | Outputs
(control/ transfer) |
Optional functions | Model | ||
---|---|---|---|---|---|---|---|
Auxiliary
outputs (SUB) |
Event
inputs |
DeviceNet
communi- cations |
|||||
96
× 96 mm |
Basic
control (1 loop) |
1 loop for standard
control Single-loop heating and cooling control |
2 points: Pulse
voltage and Pulse voltage/current |
4 | 2 | Yes | E5AR-Q4B-DRT |
2 points: Current
and Current |
E5AR-C4B-DRT | ||||||
4 points: Pulse
voltage and Pulse voltage/current and Current (2 points) |
E5AR-QC4B-DRT | ||||||
2-loop
control |
2-loop standard control
2-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control |
4 points: Pulse
voltage (2 points) and Pulse voltage/ current (2 points) |
4 | None | Yes | E5AR-QQ4W-DRT | |
4-loop
control |
4-loop standard control
2-loop heating and cooling control |
4 points: Current
(4 points) |
4 | None | Yes | E5AR-CC4WW-DRT | |
Position-
pro- portional control (1 loop) |
Single-loop position-
proportional control (See note.) |
Relay output
(1 open, 1 close) |
4 | None | Yes | E5AR-PR4F-DRT | |
Relay output
(1 open, 1 close) and 1 current (transfer) output |
E5AR-PRQ4F-DRT |
Note: Can be switched between close control and floating control.
Size | Control
type |
Control mode | Outputs
(control/ transfer) |
Optional functions | Model | ||
---|---|---|---|---|---|---|---|
Auxiliary
outputs (SUB) |
Event
inputs |
DeviceNet
communi- cations |
|||||
96
× 96 mm |
Basic
control (1 loop) |
1 loop for standard
control Single-loop heating and cooling control |
2 points: Pulse
voltage and Pulse voltage/current |
4 | 2 | Yes | E5AR-Q4B-DRT |
2 points: Current
and Current |
E5AR-C4B-DRT | ||||||
4 points: Pulse
voltage and Pulse voltage/current and Current (2 points) |
E5AR-QC4B-DRT | ||||||
2-loop
control |
2-loop standard control
2-loop heating and cooling control Single-loop cascade control Single-loop control with remote SP Single-loop proportional control |
4 points: Pulse
voltage (2 points) and Pulse voltage/ current (2 points) |
4 | None | Yes | E5AR-QQ4W-DRT | |
4-loop
control |
4-loop standard control
2-loop heating and cooling control |
4 points: Current
(4 points) |
4 | None | Yes | E5AR-CC4WW-DRT | |
Position-
pro- portional control (1 loop) |
Single-loop position-
proportional control (See note.) |
Relay output
(1 open, 1 close) |
4 | None | Yes | E5AR-PR4F-DRT | |
Relay output
(1 open, 1 close) and 1 current (transfer) output |
E5AR-PRQ4F-DRT |
Note: Can be switched between close control and floating control.
The Inspection Report can be ordered at the same time as the Digital Controller using the following model number.
Descriptions | Model |
---|---|
Inspection Report for E5AR | E5AR-K |
Descriptions | Model |
---|---|
Terminal Cover for E5AR | E53-COV14 |
Model |
---|
Y92S-L1 |
Model |
---|
Y92S-P4 |
Note: The Rubber Packing is provided with the Digital Controller.
Model |
---|
Y92H-9 |
Note: These Mounting Adapters are provided with the Digital Controller.
last update: September 15, 2016