Smart Sensors (Laser Displacement & Measurement Sensors)
last update: January 14, 2020
Model | ZX-LD40 | ZX-LD100 | ZX-LD300 | ZX-LD30V | ZX-LD40L | ZX-LD100L | ZX-LD300L | ZX-LD30VL |
---|---|---|---|---|---|---|---|---|
Optical system | Diffuse reflective | Regular
reflective |
Diffuse reflective | Regular
reflective |
||||
Light source
(wave length) |
Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max. | |||||||
EN class 2, FDA class II | ||||||||
Measurement
point |
40 mm | 100 mm | 300 mm | 30 mm | 40 mm | 100 mm | 300 mm | 30 mm |
Measurement
range |
± 10 mm | ± 40 mm | ± 200 mm | ± 2 mm | ± 10 mm | ± 40 mm | ± 200 mm | ± 2 mm |
Beam shape | Spot | Line | ||||||
Beam size*1 | 50-μm dia. | 100-μm dia. | 300-μm dia. | 75-μm dia. | 75 μm x 2 mm | 150 μm x 2 mm | 450 μm x 2 mm | 100 μm x 1.8 mm |
Resolution*2 | 2 μm | 16 μm | 300 μm | 0.25 μm | 2 μm | 16 μm | 300 μm | 0.25 μm |
Linearity*3 | ± 0.2% FS
(entire range) |
± 0.2% FS
(80 to 120 mm) |
± 2% FS
(200 to 400 mm) |
± 0.2% FS
(entire range) |
± 0.2% FS
(32 to 48 mm) |
± 0.2% FS
(80 to 120 mm) |
± 2% FS
(200 to 400 mm) |
± 0.2% FS
(entire range) |
Temperature
characteristic*4 |
± 0.03% FS/°C (Except for ZX-LD300 and ZX-LD300L, which are ± 0.1% FS/°C.)
|
|||||||
Ambient
temperature |
Incandescent lamp: 3,000 l× max. (on light receiving side) | |||||||
Ambient
illumination |
Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) | |||||||
Ambient
humidity |
Operating and storage: 35% to 85% (with no condensation) | |||||||
Insulation
resistance |
20 MΩ min. at 500 VDC | |||||||
Dielectric
strength |
1,000 VAC, 50/60 Hz for 1 min | |||||||
Vibration
resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions | |||||||
Shock
resistance (destruction) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |||||||
Degree of
protection |
IEC60529, IP50 | IEC60529, IP40 | IEC60529, IP50 | IEC60529, IP40 | ||||
Connection
method |
Connector relay (standard cable length: 500 mm) | |||||||
Weight
(packed state) |
Approx. 150 g | Approx. 250 g | Approx. 150 g | Approx. 250 g | ||||
Materials | Case: PBT
(polybutylene terephthalate), Cover: Aluminum, Lens: Glass |
Case and cover: Aluminum,
Lens: Glass |
Case: PBT
(polybutylene terephthalate), Cover: Aluminum, Lens: Glass |
Case and cover: Aluminum,
Lens: Glass |
||||
Accessories | Instruction sheet, Laser warning label (English) |
Model | ZX-LT001 | ZX-LT005 | ZX-LT010 | ZX-LT030 | ||
---|---|---|---|---|---|---|
Optical system | Through-beam | |||||
Light source (wave length) |
Visible-light semiconductor laser with a wavelength of 650 nm | |||||
EN class 1, FDA class II | ||||||
Light source (wave length) |
Maximum output |
0.2 mW max. | 0.35 mW max. | 0.2 mW max. | ||
Measurement width | 1-mm dia. | 1- to 2.5-mm dia. | 5 mm | 10 mm | 30 mm | |
Measurement distance | 0 to 500 mm | 500 to 2,000 mm | 0 to 500 mm | |||
Minimum sensing object | 8-μm dia. (opaque) | 8- to 50-μm dia. (opaque) | 0.05-mm dia. (opaque) | 0.1-mm dia. (opaque) | 0.3-mm dia. (opaque) | |
Resolution*1 | 4 μm*2 | --- | 4 μm*3 | 12 μm*4 | ||
Temperature characteristic |
±0.2% FS/°C | ±0.3% FS/°C | ||||
Ambient illumination | Incandescent lamp: 10,000 l× max. (on light-receiving side) | |||||
Ambient temperature | Operating: 0 to 50°C, Storage: -25 to 70°C (with no icing or condensation) | |||||
Ambient humidity | Operating: 35% to 85% (with no condensation) | |||||
Degree of protection | IEC60529, IP40 | |||||
Connection method | Connector relay (standard cable length: 500 mm) | |||||
Weight (packed state) | Approx. 220 g | Approx. 450 g | ||||
Cable length | Extendable up to 10 m with special extension cable. | |||||
Materials | Case | Polyether imide | Zinc die-cast | |||
Cover | Polycarbonate | |||||
Front filter | Glass | |||||
Tightening torque | 0.3 Nm max. | |||||
Accessories | Instruction sheet, Sensor Head-Amplifier Connection Cable | |||||
Optical axis adjustment seal | Mounting Bracket |
Model | ZX-LDA11-N | ZX-LDA41-N |
---|---|---|
Measurement period *1 | 150 μs | |
Possible average count settings |
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 | |
Temperature characteristic | When connected to a Reflective Sensor Head: 0.01% FS/°C, When connected to a Through-beam Sensor Head: 0.1% FS/°C |
|
Linear output *2 | Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω Voltage output: ±4 V (± 5 V, 1 to 5 V *3), Output impedance: 100 Ω |
|
Judgement outputs (3 outputs: HIGH/PASS/LOW) *1 |
NPN open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 1.2 V max. |
PNP open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 2 V max. |
Laser OFF input, zero reset input, timing input, reset input |
ON: Short-circuited with 0-V terminal or 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) |
ON: Supply voltage short-circuited or supply voltage within 1.5 V OFF: Open (leakage current: 0.1 mA max.) |
Functions | Measurement value display, present value/set value/light level/resolution display, scaling, display reverse, display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold, peak-to- peak hold, self-peak hold, self-bottom hold, average hold, delay hold, intensity mode, zero reset, initial reset, ON-delay timer, OFF-delay timer, one-shot timer, deviation, previous value comparison, sensitivity adjustment, keep/clamp switch, direct threshold value setting, position teaching, 2-point teaching, automatic teaching, hysteresis width setting, timing inputs, reset input, monitor focus, linear output compensation, (A-B) calculations14, (A+B) calculations*4, mutual interference*4, laser deterioration detection, zero reset memory, zero reset display, key lock |
|
Indications | Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment subdisplay (yellow), laser ON (green), zero reset (green), enable (green) |
|
Power supply voltage | 12 to 24 VDC ± 10%, Ripple (p-p): 10% max. | |
Current consumption | 140 mA max. with power supply voltage of 24 VDC (with Sensor connected) | |
Ambient temperature | Operating and storage: 0 to 50°C (with no icing or condensation) | |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
Insulation resistance | 20 MΩ min. at 500 VDC | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | |
Vibration resistance (destruction) |
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions | |
Shock resistance (destruction) |
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) | |
Connection method | Prewired (standard cable length: 2 m) | |
Weight (packed state) | Approx. 350 g | |
Materials | Case: PBT (polybutylene terephthalate), Cover: Polycarbonate | |
Accessories | Instruction sheet |
Model | ZX-CAL2 |
---|---|
Applicable Amplifier Units | ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41 |
Current consumption | 12 mA max. (supplied from the Smart Sensor Amplifier Unit) |
Ambient temperature | Operating: 0 to 50°C, Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Connection method | Connector |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min |
Insulation resistance | 100 MΩ (at 500 VDC) |
Vibration resistance (destructive) | 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions |
Shock resistance (destructive) | 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward) |
Materials | Display: Acrylic, Case: ABS resin |
Weight (packed state) | Approx. 50 g |
Item | ZX-SF11 | |
---|---|---|
Current consumption | 60 mA max. (supplied by the Amplifier Unit) | |
Applicable Amplifier Units | ZX Series | |
Applicable Amplifier Unit
versions |
ZX-LDA[]1-N Ver. 2.100 or higher
ZX-EDA[]1 Ver. 1.100 or higher ZX-TDA[]1 Ver. 1.000 or higher |
|
Max. No. of Amplifier Units | 5 (max. 2 with calculating unit) | |
Commu-
nications functions |
Communications port | RS-232C port (9-pin D-Sub Connector) |
Communications
protocol |
CompoWay/F* | |
Baud rate | 38,400 bps | |
Data configuration | Data bits: 8, Parity: none, Start bits: 1, Stop bits: 1, Flow control: none | |
Indicators | Power supply: green, Sensor communications: green, Sensor communications
error: red, External terminal communications: green, External terminal communications error: red |
|
Protective circuits | Reverse polarity protection | |
Ambient temperature | Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation) | |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max. | |
Materials | Case: PBT (polybutylene terephthalate), Cover: Polycarbonate | |
Accessories | Instruction sheet, 2 clamps |
* Contact your OMRON representative for CompoWay/F communications specifications.
last update: January 14, 2020