Digital Fiber Amplifier Unit
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: October 1, 2015
Type | Standard models | Ultra-long-term
APC models |
High-speed
response models |
||
---|---|---|---|---|---|
Standard models | Model for Sensor
Communications Unit |
||||
Model | E3X-DA[]-S
([]: 21/51/7/9) |
E3X-DA0-S *1 | E3X-DA[]R-S
([]: 21/51/7/9) |
E3X-DA[]F-S
([]: 21/51/7/9) |
|
Light source (wavelength) | Red,4-element LED (625 nm) | ||||
Power supply voltage | 12 to 24 VDC ± 10%, ripple (p-p) 10% max. | Supplied from the
connector through the Sensor Communications Unit |
12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||
Power consumption | Normal mode: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA
max. at 12 VDC) Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC) |
||||
Control output/APC alarm
output *1 |
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max. |
||||
External input *2 | No-voltage input
(contact/transistor) *3 |
--- | No-voltage input
(contact/transistor) *3 |
--- | |
Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output
reverse polarity protection |
||||
Re-
sponse time |
Super-high-
speed Mode *4 |
Operate or reset:
80 μs |
--- | Operate or reset:
80 μs |
NPN output:
Operate: 46 μs, Reset: 48 μs PNP output: Operate: 51 μs, Reset: 53 μs |
High-speed Mode | Operate or reset: 250 μs | --- | |||
Standard Mode | Operate or reset: 1 ms | ||||
High-resolution
Mode |
Operate or reset: 4 ms | ||||
Tough Mode | Operate or reset: 16 ms | ||||
Sensitivity setting | Teaching or manual method | ||||
Func-
tions |
Power tuning | Light emission power and reception gain, digital control method | |||
Differential
detection |
Switchable between Single-edge and Double-edge Detection
Modes. Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms. Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms |
--- | |||
Automatic power
control (APC) |
Always enabled.
High-speed control of emission current Wide-range APC for the E3X-DA[]R-S |
||||
Timer | Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay
timer |
||||
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms
increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) |
|||||
ATC | Provided | ||||
APC margin
display |
--- | Provided | --- | ||
Slow-motion
display |
--- | Provided | |||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting
settings |
Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Mutual
interference prevention |
Possible for up to 10 units *5 | --- | |||
ECO Mode *6 | Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital
display OFF). |
||||
External input
setting *2 |
Select from teaching operations, power tuning, zero reset,
emitter OFF, or ATC start. |
--- | |||
Output setting | Select from output for each channel,
area output, or self-diagnosis. |
--- | |||
Indicator | Operation indicator for channel 1 (orange)
Operation indicator for channel 2 (orange) |
Operation indicator
for channel 1 (orange) APC alarm output indicator (orange) |
Operation indicator
for channel 1 (orange) Power tuning indicator (orange) |
||
Digital display | Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch
on Catalog.) |
||||
Display orientation | Switching between normal/reversed display is possible. | ||||
Key lock | Key lock | Key lock/Easy key lock. | |||
Ambient illumination
(Receiver side) |
Incandescent lamp: 10,000 lx max.
Sunlight: 20,000 lx max. |
||||
Maximum connectable
Units |
16 (The ambient temperature specification depends on the number of connected
units.) *7 |
||||
Ambient temperature
range |
Operating: Groups of 1 to 2 Amplifiers: -25 to 55°C
Groups of 3 to 10 Amplifiers: -25 to 50°C Groups of 11 to 16 Amplifiers: -25 to 45°C *8 |
||||
Storage: - 30 to 70 °C (with no icing or condensation) | |||||
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
Vibration resistance
(Destruction) |
10 to 55 Hz with a
1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
10 to 150 Hz with a
0.7-mm double amplitude for 80 min each in X, Y, and Z directions |
10 to 55 Hz with a 1.5-mm double
amplitude for 2 hours each in X, Y, and Z directions |
||
Shock resistance
(Destruction) |
500 m/s2 for 3 times
each in X, Y, and Z directions |
200 m/s2 for 3
times each in X, Y, and Z directions |
500 m/s2 for 3 times each in X, Y, and
Z directions |
||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | ||||
Connection method | Pre-wired (standard
cable length: 2 m) or wire-saving connector |
Connector for
Sensor Communications Unit |
Pre-wired (standard cable length: 2 m) or
wire-saving connector |
||
Weight (packed state) | Pre-wired Models:
Approx. 100 g, Wire- saving Connector Models: Approx. 55 g |
Approx. 55 g | Pre-wired Models: Approx. 100 g, Wire-
saving Connector Models: Approx. 55 g |
||
Mate-
rials |
Case | Polybutylene terephthalate (PBT) | |||
Cover | Polycarbonate (PC) | ||||
Accessories | Instruction Manual |
Contact input (relay or switch) | Non-contact input (transistor) | |
---|---|---|
NPN | ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.) |
PNP | ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V. |
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.) |
Model | E3X-CN21/22/11 | E3X-CN12 | |
---|---|---|---|
Rated current | 2.5 A | ||
Rated voltage | 50 V | ||
Contact resistance | 20 mΩ max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Fiber Amplifier Unit and the adjacent connector. It does not include the conductor resistance of the cable.) |
||
No. of insertions | Destruction: 50 times
(The figure for the number of insertions is for connection to the Fiber Amplifier Unit and the adjacent connector.) |
||
Materials | Housing | Polybutylene terephthalate (PBT) | |
Contacts | Phosphor bronze/gold-plated nickel | ||
Weight (packed state) | Approx. 55 g | Approx. 25 g |
Note: The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method |
Sensing
direction |
Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high-speed mode |
||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 2,000 | 1,400 | 1,000 | 700 | 280 |
E32-LT11N 2M | 4,000 * | 4,000 * | 3,500 | 2,300 | 920 | |||
Straight | E32-T11R 2M | 2,000 | 1,400 | 1,000 | 700 | 280 | ||
E32-LT11 2M | 4,000 * | 4,000 * | 4,000 * | 2,700 | 1,080 | |||
E32-LT11R 2M | 4,000 * | 4,000 * | 3,500 | 2,300 | 920 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 110 | 80 | 50 | 46 | 14 |
E32-C21N 2M | 290 | 150 | 130 | 90 | 39 | |||
M4 | E32-D21N 2M | 840 | 600 | 350 | 240 | 100 | ||
M6 | E32-C11N 2M | 780 | 560 | 350 | 320 | 100 | ||
E32-LD11N 2M | 840 | 600 | 350 | 240 | 100 | |||
Straight | M3 | E32-D21R 2M | 140 | 100 | 60 | 40 | 16 | |
E32-C31 2M | 330 | 240 | 150 | 100 | 44 | |||
E32-C31M 1M | ||||||||
M4 | E32-D211R 2M | 140 | 100 | 60 | 40 | 16 | ||
M6 | E32-D11R 2M | 840 | 600 | 350 | 240 | 100 | ||
E32-CC200 2M | 1,400 | 1,000 | 600 | 400 | 180 | |||
E32-LD11 2M | 860 | 610 | 360 | 250 | 110 | |||
E32-LD11R 2M | 840 | 600 | 350 | 240 | 100 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Size | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam | 1 dia. | Top-view | E32-T223R 2M | 450 | 300 | 250 | 150 | 60 |
1.5 dia. | E32-T22B 2M | 680 | 480 | 400 | 220 | 90 | ||
3 dia. | E32-T12R 2M | 2,000 | 1,400 | 1,000 | 700 | 280 | ||
Side-view | E32-T14LR 2M | 750 | 550 | 450 | 260 | 100 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 140 | 100 | 60 | 40 | 16 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 28 | 20 | 12 | 8 | 4 | ||
3 dia. | E32-D22R 2M | 140 | 100 | 60 | 40 | 16 | ||
E32-D221B 2M | 300 | 220 | 140 | 90 | 40 | |||
E32-D32L 2M | 700 | 500 | 300 | 200 | 90 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 70 | 50 | 30 | 20 | 8 |
Sensing method | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high-speed mode |
|||
Through-beam | Top-view | E32-T15XR 2M | 2,000 | 1,400 | 1,000 | 700 | 280 |
Side-view | E32-T15YR 2M | 750 | 550 | 450 | 260 | 100 | |
Flat-view | E32-T15ZR 2M | ||||||
Reflective | Top-view | E32-D15XR 2M | 840 | 600 | 350 | 240 | 100 |
Side-view | E32-D15YR 2M | 200 | 140 | 100 | 52 | 24 | |
Flat-view | E32-D15ZR 2M |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
|||
Through-beam | Side-view | E32-T24R 2M | 170 | 120 | 100 | 50 | 20 |
E32-T24E 2M | 450 | 300 | 250 | 150 | 60 | ||
Top-view | E32-T21-S1 2M | 510 | 360 | 300 | 170 | 68 | |
E32-T33 1M | 150 | 110 | 90 | 50 | 20 | ||
E32-TC200BR 2M | 2,000 | 1,400 | 1,000 | 700 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 70 | 52 | 30 | 20 | 8 |
E32-D24-S2 2M | 120 | 80 | 53 | 45 | 14 | ||
Top-view | E32-D43M 1M | 28 | 20 | 12 | 8 | 4 | |
E32-D331 2M | 14 | 10 | 6 | 4 | 2 | ||
E32-D33 2M | 70 | 50 | 30 | 20 | 8 | ||
E32-D32-S1 0.5M | 63 | 43 | 27 | 18 | 7 | ||
E32-D31-S1 0.5M | |||||||
E32-DC200F4R 2M | 140 | 100 | 60 | 40 | 16 | ||
E32-D22-S1 2M | 250 | 170 | 110 | 72 | 30 | ||
E32-D21-S3 2M | |||||||
E32-DC200BR 2M | 840 | 600 | 350 | 240 | 100 | ||
E32-D25-S3 2M | 250 | 170 | 110 | 72 | 30 |
Type | Spot
diameter |
Center
distance (mm) |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Variable
spot |
0.1 to
0.6 dia. |
6 to 5 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | ||||
0.3 to
1.6 dia. |
10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | |||||
Parallel
light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | ||||
E32-C31N 2M + E39-F3C | ||||||||
Integrated
lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | ||||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | |||||
Small-
spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | ||||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | ||||||
E32-C31N 2M + E39-F3A-5 | ||||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | |||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | ||||||
E32-C31N 2M + E39-F3B | ||||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | |||||
E32-C11N 2M + E39-F18 |
Type | Sensing
direction |
Aper-
ture angle |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam
Integrated lens |
Right-angle | 15 ° | E32-LT11N 2M | 4,000 *2 | 4,000 *2 | 3,500 | 2,300 | 920 |
Top-view | 10 ° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
15 ° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,700 | 1,080 | ||
E32-LT11R 2M | 4,000 *2 | 4,000 *2 | 3,500 | 2,300 | 920 | |||
Side-view | 30 ° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
Through-
beam models with lenses |
Right-angle | 12 ° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 |
6 ° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Top-view | 12 ° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000*2 | 2,000 | |
6 ° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Side-view | 60 ° | E32-T11R 2M + E39-F2 | 1,450 | 1,040 | 800 | 500 | 200 | |
Top-view | 12 ° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
6 ° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60 ° | E32-T11 2M + E39-F2 | 2,300 | 1,640 | 1,320 | 860 | 320 | |
Top-view | 12 ° | E32-T51R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,900 | 1,500 | |
6 ° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60 ° | E32-T51R 2M + E39-F2 | 1,400 | 1,000 | 720 | 500 | 200 | |
Top-view | 12 ° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,700 | 1,000 | |
6 ° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Side-view | 60 ° | E32-T81R-S 2M + E39-F2 | 1,000 | 720 | 550 | 360 | 140 | |
Top-view | 12 ° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
6 ° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
Side-view | 60 ° | E32-T61-S 2M + E39-F2 | 1,680 | 1,200 | 900 | 600 | 240 | |
Top-view | 12 ° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,300 | 1,400 | |
6 ° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Reflective
Integrated lens |
Top-view | 4 ° | E32-D16 2M | 40 to 2,800 | 40 to 2,000 | 40 to 1,400 | 40 to 900 | 40 to 480 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam | Side-view | 1.5 ° | E32-A03 2M | 3,220 | 2,300 | 1,780 | 1,200 | 500 |
E32-A03-1 2M | ||||||||
3.4 ° | E32-A04 2M | 1,280 | 920 | 680 | 450 | 200 | ||
4 ° | E32-T24SR 2M | 4,000 * | 2,960 | 2,200 | 1,460 | 580 | ||
E32-T24S 2M | 4,000 * | 3,500 | 2,600 | 1,740 | 700 | |||
E32-T22S 2M | 4,000 * | 4,000 * | 3,800 | 2,500 | 1,000 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing method | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Limited-reflective | Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||
E32-L24S 2M | 0 to 4 | ||||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Sensing
method |
Feature | Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Retro-
reflective |
Film detection | M3 | E32-C31 2M + E39-F3R
+ E39-RP37 |
250 | 200 | - | ||
Square | - | E32-R16 2M | 150 to 1,500 | |||||
Threaded Models | M6 | E32-R21 2M | 10 to 250 | |||||
Hex-shaped | E32-LR11NP 2M
+ E39-RP1 |
1,350 | 1,270 | 1,200 | 1,000 | 550 |
Sensing
method |
Feature | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Limited-
reflective |
Small size | Flat-view | E32- L24S 2M | 0 to 4 | ||||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||||
Glass substrate
alignment, 70 °C |
E32-A08 2M | 10 to 20 | - | |||||
Standard/
long-distance |
E32-A12 2M | 12 to 30 | - | |||||
Side view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | |||||
Glass substrate
mapping, 70 °C |
Top-view | E32-A09 2M | 15 to 38 | - |
Sensing
method |
Type | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-
beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 |
Chemical/
oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
E32-T11F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,600 | 1,000 | |||
Side-view | E32-T14F 2M | 1,400 | 1,000 | 800 | 500 | 200 | ||
Chemical/oil-
resistant at 150 °C |
Top-view | E32-T51F 2M | 4,000 *1 | 3,600 | 2,800 | 1,800 | 700 | |
Reflective | Semiconductors:
Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended detection distance: 22 mm) |
||||
Semiconductors:
Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended detection distance: 35 mm) |
||||||
Chemical/
oil-resistant |
E32-D12F 2M | - *2 | 320 | 190 | 130 | 60 | ||
Chemical-resistant
cable |
E32-D11U 2M | 840 | 600 | 350 | 240 | 100 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Sensing
method |
Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-high-
speed mode |
|||
Through-beam | 1.5 dia. | E32-T22B 2M | 680 | 480 | 400 | 220 | 90 |
M3 | E32-T21 2M | ||||||
M4 | E32-T11 2M | 2,500 | 1,800 | 1,350 | 900 | 360 | |
Square | E32-T25XB 2M | 500 | 360 | 300 | 170 | 70 | |
Reflective | 1.5 dia. | E32-D22B 2M | 140 | 100 | 60 | 40 | 16 |
M3 | E32-D21 2M | ||||||
3 dia. | E32-D221B 2M | 300 | 220 | 140 | 90 | 40 | |
M4 | E32-D21B 2M | ||||||
M6 | E32-D11 2M | 840 | 600 | 350 | 240 | 100 | |
Square | E32-D25XB 2M | 240 | 170 | 100 | 60 | 30 |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
|||
Through-beam | 100 °C | E32-T51R 2M | 1,600 | 1,100 | 800 | 560 | 225 |
150 °C | E32-T51 2M | 2,800 | 2,000 | 1,500 | 1,000 | 400 | |
200 °C | E32-T81R-S 2M | 1,000 | 720 | 550 | 360 | 140 | |
350 °C | E32-T61-S 2M | 1,680 | 1,200 | 900 | 600 | 240 | |
Reflective | 100 °C | E32-D51R 2M | 670 | 480 | 280 | 190 | 80 |
150 °C | E32-D51 2M | 1,120 | 800 | 450 | 320 | 144 | |
200 °C | E32-D81R-S 2M | 420 | 300 | 180 | 120 | 54 | |
300 °C | E32-A08H2 2M | 10 to 20 | - | ||||
E32-A09H2 2M | 20 to 30 (center 25) | - | |||||
350 °C | E32-D611-S 2M | 420 | 300 | 180 | 120 | 54 | |
E32-D61-S 2M | |||||||
400 °C | E32-D73-S 2M | 280 | 200 | 120 | 80 | 36 |
Sensing
method |
Type | Sensing
width |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 3,100 | 2,200 | 1,700 | 1,120 | 440 |
E32-T16JR 2M | 2,750 | 2,000 | 1,500 | 960 | 380 | |||
30 mm | E32-T16WR 2M | 4,000 * | 3,400 | 2,600 | 1,700 | 680 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 700 | 500 | 300 | 200 | 90 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Tube
diameter |
Feature | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Tube-mounting | 3.2/6.4/
9.5 dia |
Stable residual
quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of
3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
||||
8 to 10 dia | Mounting at
multi levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of
8 to 10 mm, Recommended wall thickness: 1 mm |
|||||
No
restrictions |
Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions
on diameter) |
|||||
Liquid contact
(heat-resistant up to 200 °C) |
- | - | E32-D82F1 4M | Liquid-contact Type |
Sensing
method |
Heat-
resistant temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-high-
speed mode |
|||
Through-beam | 120 °C | E32-T51V 1M | 720 | 520 | 400 | 260 | 100 |
E32-T51V 1M + E39-F1V | 2,000 * | 2,000 * | 2,000 * | 1,360 | 520 | ||
200 °C | E32-T84SV 1M | 1,760 | 1,250 | 950 | 640 | 260 |
* The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Sensing
method |
Application | Operating
temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Limited-
reflective |
Glass presence
detection |
70 °C | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||
Glass substrate
alignment |
E32-A08 2M | 10 to 20 | - | |||||
300 °C | E32-A08H2 2M | |||||||
70 °C | E32-A12 2M | 12 to 30 | - | |||||
Glass substrate
mapping |
E32-A09 2M | 15 to 38 | - | |||||
300 °C | E32-A09H2 2M | 20 to 30 | - | |||||
Wet processes:
Cleaning, Resist developing and etching |
60 °C | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended detection distance: 22 mm) |
|||||
Wet process:
Resist stripping |
85 °C | E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended detection distance: 35 mm) |
|||||
Through-
beam |
Wafer mapping | 70 °C | E32-A03 2M | 3,220 | 2,300 | 1,780 | 1,200 | 500 |
E32-A03-1 2M | ||||||||
E32-A04 2M | 1,280 | 920 | 680 | 450 | 200 | |||
E32-T24SR 2M | 4,000 * | 2,960 | 2,200 | 1,460 | 580 | |||
E32-T24S 2M | 4,000 * | 3,500 | 2,600 | 1,740 | 700 |
* The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 1,000 | 700 | 500 | 350 | 140 |
E32-LT11N 2M | 3,200 | 2,300 | 1,750 | 1,150 | 460 | |||
Straight | E32-T11R 2M | 1,000 | 700 | 530 | 350 | 140 | ||
E32-LT11 2M | 3,800 | 2,700 | 2,050 | 1,350 | 540 | |||
E32-LT11R 2M | 3,200 | 2,300 | 1,750 | 1,150 | 460 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 55 | 40 | 25 | 23 | 7 |
E32-C21N 2M | 145 | 75 | 65 | 45 | 20 | |||
M4 | E32-D21N 2M | 420 | 300 | 175 | 120 | 50 | ||
M6 | E32-C11N 2M | 390 | 280 | 175 | 160 | 50 | ||
E32-LD11N 2M | 420 | 300 | 170 | 120 | 50 | |||
Straight | M3 | E32-D21R 2M | 70 | 50 | 30 | 20 | 8 | |
E32-C31 2M | 165 | 120 | 75 | 50 | 22 | |||
E32-C31M 1M | ||||||||
M4 | E32-D211R 2M | 70 | 50 | 30 | 20 | 8 | ||
M6 | E32-D11R 2M | 420 | 300 | 170 | 120 | 50 | ||
E32-CC200 2M | 700 | 500 | 300 | 200 | 90 | |||
E32-LD11 2M | 430 | 305 | 180 | 125 | 55 | |||
E32-LD11R 2M | 420 | 300 | 170 | 120 | 50 |
Sensing
method |
Size | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-
beam |
1 dia. | Top-view | E32-T223R 2M | 220 | 160 | 130 | 75 | 30 |
1.5 dia. | E32-T22B 2M | 340 | 240 | 200 | 110 | 45 | ||
3 dia. | E32-T12R 2M | 1,000 | 700 | 530 | 350 | 140 | ||
Side-view | E32-T14LR 2M | 370 | 270 | 210 | 130 | 50 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 70 | 50 | 30 | 20 | 8 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 15 | 11 | 6 | 4 | 2 | ||
3 dia. | E32-D22R 2M | 70 | 50 | 30 | 20 | 8 | ||
E32-D221B 2M | 150 | 110 | 70 | 45 | 20 | |||
E32-D32L 2M | 350 | 250 | 150 | 100 | 45 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 35 | 25 | 16 | 10 | 4 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
|||
Through-beam | Top-view | E32-T15XR 2M | 1,000 | 700 | 530 | 350 | 140 |
Side-view | E32-T15YR 2M | 370 | 270 | 210 | 130 | 50 | |
Flat-view | E32-T15ZR 2M | ||||||
Reflective | Top-view | E32-D15XR 2M | 420 | 300 | 170 | 120 | 50 |
Side-view | E32-D15YR 2M | 100 | 70 | 40 | 26 | 12 | |
Flat-view | E32-D15ZR 2M |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-high-
speed mode |
|||
Through-beam | Side-view | E32-T24R 2M | 85 | 60 | 50 | 25 | 10 |
E32-T24E 2M | 225 | 150 | 125 | 75 | 30 | ||
Top-view | E32-T21-S1 2M | 255 | 180 | 150 | 85 | 34 | |
E32-T33 1M | 75 | 55 | 45 | 25 | 10 | ||
E32-TC200BR 2M | 1,000 | 700 | 530 | 350 | 140 | ||
Reflective | Side-view | E32-D24R 2M | 35 | 26 | 15 | 10 | 4 |
E32-D24-S2 2M | 60 | 40 | 26 | 23 | 7 | ||
Top-view | E32-D43M 1M | 15 | 11 | 6 | 4 | 2 | |
E32-D331 2M | 7 | 5 | 3 | 2 | 0.8 | ||
E32-D33 2M | 35 | 25 | 16 | 10 | 4 | ||
E32-D32-S1 0.5M | 31 | 21 | 13 | 9 | 3 | ||
E32-D31-S1 0.5M | |||||||
E32-DC200F4R 2M | 70 | 50 | 30 | 20 | 8 | ||
E32-D22-S1 2M | 125 | 85 | 55 | 36 | 15 | ||
E32-D21-S3 2M | |||||||
E32-DC200BR 2M | 420 | 300 | 170 | 120 | 50 | ||
E32-D25-S3 2M | 125 | 85 | 55 | 36 | 15 |
Type | Spot
diameter |
Center
distance (mm) |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Variable spot | 0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | ||||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | |||||
Parallel light | 4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | ||||
E32-C31N 2M + E39-F3C | ||||||||
Integrated
lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | ||||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | |||||
Small-spot | 0.1 dia. | 7 | E32-C41 1M +
E39-F3A-5 |
Spot diameter of 0.1 mm at 7 mm. | ||||
0.5 dia. | E32-C31 2M +
E39-F3A-5 |
Spot diameter of 0.5 mm at 7 mm. | ||||||
E32-C31N 2M +
E39-F3A-5 |
||||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | |||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | ||||||
E32-C31N 2M + E39-F3B | ||||||||
3 dia. | 50 | E32-CC200 2M +
E39-F18 |
Spot diameter of 3 mm at 50 mm. | |||||
E32-C11N 2M + E39-F18 |
Type | Sensing
direction |
Aper-
ture angle |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-
beam Integrated lens |
Right-angle | 15 ° | E32-LT11N 2M | 3,200 | 2,300 | 1,750 | 1,150 | 460 |
Top-view | 10 ° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 10,000 | 4,000 | |
15 ° | E32-LT11 2M | 3,800 | 2,700 | 2,050 | 1,350 | 540 | ||
E32-LT11R 2M | 3,200 | 2,300 | 1,750 | 1,150 | 460 | |||
Side-view | 30 ° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 3,400 | 2,250 | 900 | |
Through-
beam models with lenses |
Right-angle | 12 ° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 3,700 | 2,400 | 970 |
6 ° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Top-view | 12 ° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 3,700 | 2,400 | 970 | |
6 ° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Side-view | 60 ° | E32-T11R 2M + E39-F2 | 725 | 520 | 400 | 250 | 100 | |
Top-view | 12 ° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 3,600 | 2,300 | 930 | |
6 ° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,300 | ||
Side-view | 60 ° | E32-T11 2M + E39-F2 | 1,150 | 820 | 660 | 430 | 160 | |
Top-view | 12 ° | E32-T51R 2M + E39-F1 | 4,000 *2 | 3,900 | 2,900 | 1,900 | 760 | |
6 ° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | 1,400 | ||
Side-view | 60 ° | E32-T51R 2M + E39-F2 | 700 | 500 | 360 | 250 | 100 | |
Top-view | 12 ° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 2,650 | 2,100 | 1,300 | 520 | |
6 ° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 3,600 | 2,300 | 900 | ||
Side-view | 60 ° | E32-T81R-S 2M + E39-F2 | 500 | 360 | 280 | 180 | 70 | |
Top-view | 12 ° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 3,400 | 2,200 | 900 | |
6 ° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,900 | 1,500 | ||
Side-view | 60 ° | E32-T61-S 2M + E39-F2 | 840 | 600 | 450 | 300 | 120 | |
Top-view | 12 ° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 3,400 | 2,660 | 1,150 | 700 | |
6 ° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,600 | ||
Reflective
Integrated lens |
Top-view | 4 ° | E32-D16 2M | 40 to 1,400 | 40 to 1,000 | 40 to 700 | 40 to 450 | 40 to 240 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-
beam |
Side-view | 1.5 ° | E32-A03 2M | 1,610 | 1,150 | 890 | 600 | 250 |
E32-A03-1 2M | ||||||||
3.4 ° | E32-A04 2M | 640 | 460 | 340 | 225 | 100 | ||
4 ° | E32-T24SR 2M | 2,100 | 1,500 | 1,100 | 750 | 300 | ||
E32-T24S 2M | 2,400 | 1,750 | 1,300 | 870 | 350 | |||
E32-T22S 2M | 3,500 | 2,500 | 1,900 | 1,250 | 500 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-high-
speed mode |
|||
Limited-reflective | Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||
E32-L24S 2M | 0 to 4 | ||||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Sensing
method |
Feature | Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Retro-
reflective |
Film detection | M3 | E32-C31 2M + E39-F3R
+ E39-RP37 |
250 | 200 | 150 | 100 | 50 |
Square | - | E32-R16 2M | 150 to 1,500 | |||||
Threaded Models | M6 | E32-R21 2M | 10 to 250 | |||||
Hex-shaped | E32-LR11NP 2M
+ E39-RP1 |
675 | 630 | 600 | 500 | 275 |
Sensing
method |
Feature | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Limited-
reflective |
Small size | Flat-view | E32- L24S 2M | 0 to 4 | ||||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||||
Glass substrate
alignment, 70 °C |
E32-A08 2M | 10 to 20 | ||||||
Standard/
long-distance |
E32-A12 2M | 12 to 30 | ||||||
Side view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | |||||
Glass substrate
mapping, 70 °C |
Top-view | E32-A09 2M | 15 to 38 |
Sensing
method |
Type | Sensing
direction |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-
beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 3,100 | 1,200 |
Chemical/oil-resistant | Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 3,000 | 2,000 | 800 | |
E32-T11F 2M | 3,500 | 2,500 | 2,000 | 1,300 | 520 | |||
Side-view | E32-T14F 2M | 700 | 500 | 400 | 250 | 100 | ||
Chemical/
oil-resistant at 150 °C |
Top-view | E32-T51F 2M | 2,500 | 1,800 | 1,400 | 900 | 350 | |
Reflective | Semiconductors:
Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended
detection distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended detection distance: 22 mm) |
||||
Semiconductors:
Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended
detection distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended detection distance: 35 mm) |
||||||
Chemical/oil-resistant | E32-D12F 2M | - *2 | 160 | 95 | 65 | 30 | ||
Chemical-resistant
cable |
E32-D11U 2M | 420 | 300 | 170 | 120 | 50 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Sensing method | Size | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-resolution
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Through-beam | 1.5 dia. | E32-T22B 2M | 340 | 240 | 200 | 110 | 45 |
M3 | E32-T21 2M | ||||||
M4 | E32-T11 2M | 1,250 | 900 | 680 | 450 | 180 | |
Square | E32-T25XB 2M | 250 | 180 | 150 | 85 | 35 | |
Reflective | 1.5 dia. | E32-D22B 2M | 70 | 50 | 30 | 20 | 8 |
M3 | E32-D21 2M | ||||||
3 dia. | E32-D221B 2M | 150 | 110 | 70 | 45 | 20 | |
M4 | E32-D21B 2M | ||||||
M6 | E32-D11 2M | 420 | 300 | 170 | 120 | 50 | |
Square | E32-D25XB 2M | 120 | 85 | 50 | 30 | 15 |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
|||
Through-beam | 100 °C | E32-T51R 2M | 800 | 560 | 425 | 280 | 110 |
150 °C | E32-T51 2M | 1,400 | 1,000 | 760 | 500 | 200 | |
200 °C | E32-T81R-S 2M | 500 | 360 | 280 | 180 | 70 | |
350 °C | E32-T61-S 2M | 840 | 600 | 450 | 300 | 120 | |
Reflective | 100 °C | E32-D51R 2M | 330 | 240 | 135 | 95 | 40 |
150 °C | E32-D51 2M | 560 | 400 | 230 | 160 | 72 | |
200 °C | E32-D81R-S 2M | 210 | 150 | 90 | 60 | 27 | |
300 °C | E32-A08H2 2M | 10 to 20 | |||||
E32-A09H2 2M | 20 to 30 (center 25) | ||||||
350 °C | E32-D611-S 2M | 210 | 150 | 90 | 60 | 27 | |
E32-D61-S 2M | |||||||
400 °C | E32-D73-S 2M | 140 | 100 | 60 | 40 | 18 |
Sensing
method |
Type | Sensing
width |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 1,550 | 1,100 | 840 | 560 | 220 |
E32-T16JR 2M | 1,370 | 980 | 750 | 480 | 190 | |||
30 mm | E32-T16WR 2M | 2,000 | 1,700 | 1,300 | 850 | 340 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 350 | 250 | 150 | 100 | 45 |
Sensing
method |
Tube
diameter |
Feature | Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Tube-mounting | 3.2/6.4/
9.5 dia |
Stable residual
quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of
3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
||||
8 to 10 dia | Mounting at
multi levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of
8 to 10 mm, Recommended wall thickness: 1 mm |
|||||
No
restrictions |
Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions
on diameter) |
|||||
Liquid contact
(heat-resistant up to 200 °C) |
- | - | E32-D82F1 4M | Liquid-contact Type |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-high-
speed mode |
|||
Through-
beam |
120 °C | E32-T51V 1M | 360 | 260 | 200 | 130 | 50 |
E32-T51V 1M + E39-F1V | 1,890 | 1,350 | 1,000 | 680 | 260 | ||
200 °C | E32-T84SV 1M | 880 | 630 | 480 | 320 | 130 |
Sensing
method |
Application | Operating
temperature |
Model | Sensing distance (mm) | ||||
---|---|---|---|---|---|---|---|---|
Tough
mode |
High-
resolution mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Limited-
reflective |
Glass presence
detection |
70 °C | E32-L16-N 2M | 0 to 15 | 0 to 12 | |||
Glass substrate
alignment |
E32-A08 2M | 10 to 20 | ||||||
300 °C | E32-A08H2 2M | |||||||
70 °C | E32-A12 2M | 12 to 30 | ||||||
Glass substrate
mapping |
E32-A09 2M | 15 to 38 | ||||||
300 °C | E32-A09H2 2M | 20 to 30 (center 25) | ||||||
Wet processes:
Cleaning, Resist developing and etching |
60 °C | E32-L11FP 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended detection distance: 22 mm) |
|||||
Wet process:
Resist stripping |
85 °C | E32-L11FS 2M | 8 to 20 mm from tip of lens (Recommended detection
distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended detection distance: 35 mm) |
|||||
Through-
beam |
Wafer mapping | 70 °C | E32-A03 2M | 1,610 | 1,150 | 890 | 600 | 250 |
E32-A03-1 2M | ||||||||
E32-A04 2M | 640 | 460 | 340 | 225 | 100 | |||
E32-T24SR 2M | 2,100 | 1,500 | 1,100 | 750 | 300 | |||
E32-T24S 2M | 2,400 | 1,750 | 1,300 | 870 | 350 |
last update: October 1, 2015