Page top

Industrial Automation

Industrial Automation

E32-LT11N / LD11N / LR11NP

Hex-shaped Fiber Unit

E32-LT11N / LD11N / LR11NP

Fiber Units with Build-in Lenses provide more stable detection and simpler, more reliable installation.

Through-beam Fiber Units

Type Appearance
(mm)
Bending
radius
of cable
(mm)
Sensing distance
(mm)*1
Optical
axis
diameter
(minimum
sensing
object)
(mm)*2
Models
Size Aperture
angle
E3X-HD E3NX-FA
M4 Approx.
15°
[Build-in]
[Lens]
3275_lu_1_1
Flexible,
R2
GIGA: 4,000 *2
HS: 2,300
ST: 3,500
SHS: 920
GIGA: 4,000 *2
HS: 3,450
ST: 4,000 *2
SHS: 920
2.3 dia.
(0.1 dia./
0.03 dia.)
E32-LT11N 2M

Reflective Fiber Units/Retro-reflective Fiber Units

Type Appearance
(mm)
Bending
radius
of cable
(mm)
Sensing distance
(mm)*1, 4
Optical
axis
diameter
(minimum
sensing
object)
(mm)*3
Models
Sensing
method
Size Aperture
angle
E3X-HD E3NX-FA
Reflective M3 Approx.
60°
Coaxial
3275_lu_2_1
Flexible,
R2
GIGA: 290
HS: 90
ST: 130
SHS: 39
GIGA: 440
HS: 130
ST: 190
SHS: 39
(5 μm dia./
2 μm dia.)
E32-C21N 2M
M4
3275_lu_2_2
GIGA: 840
HS: 240
ST: 350
SHS: 100
GIGA: 1,260
HS: 360
ST: 520
SHS: 100
E32-D21N 2M
M6 Approx.
15°
[Build-in]
[Lens]
3275_lu_2_3
GIGA: 840
HS: 240
ST: 350
SHS: 100
GIGA: 1,260
HS: 360
ST: 520
SHS: 100
(0.1 dia./
0.03 dia.)
E32-LD11N 2M
Retro-
reflective
for
transparent
object
detection
M6 Approx.
15°
[Build-in]
[Lens]
3275_lu_2_4
Flexible,
R2
GIGA: 1,350
HS: 1,000
ST: 1,200
SHS: 550
GIGA: 2,020
HS: 1,500
ST: 1,800
SHS: 550
E32-LR11NP 2M
+
E39-RP1
(Optional reflector)

*1. The following mode names and response times apply to the modes given in the Sensing distance column.
      E3X-HD GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
                          SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
      E3NX-FA GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
                          SHS: Super-high-speed mode (30 μs)
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
*3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
      with the sensing distance and sensitivity set to the optimum values.
      The first value is for the E3X-HD and the second value is for the E3NX-FA.
*4. The sensing distances for Reflective Fiber Units are for white paper.
      The sensing distances for the E32-LD11N 2M are for glossy white paper.
Note. Objects with a high reflection factor may cause the Retro-reflective Fiber Sensor to detect reflected light as incident light.
         Detection may be unstable depending on the type of transparent object. Check suitability beforehand.

Accessories

Appearance Models Quantity Remarks
3275_lu_3_1
E39-F9W13 1 1.3-dia. Attachment
Provided with applicable Fiber Units.
Order this accessory separately if you lose or damage it.