Item Model |
||||
Appearance |
|
|
|
|
Phase available |
Single |
Single/Optional 2 legs |
Single / Three-phase, 2/3 legs |
|
Maximum load voltage (AC/DC) |
75 to 264 VAC |
24 to 480 VAC; |
24 to 480 VAC |
100 to 480 VAC |
Maximum current available |
5 A, 10 A, 20 A |
5 A, 10 A, 20 A, 40 A, 50 A, 75 A, 90 A |
10 A, 20 A, 30 A, 40 A, 50 A, 60 A |
15 A, 25 A, 35 A, 45 A |
Firing method |
Zero crossover |
Zero crossover and standard ON/OFF | ||
Signal input |
VDC logic signal |
VAC/VDC logic signal |
VDC logic signal |
|
Soft-start function |
Not supported |
|||
Duty setting |
Not supported |
|||
Built-in current transformer |
No |
|||
Support external CT |
No |
|||
Communication option |
Not supported |
|||
Type of mounting |
Screw type |
|||
Heat sink option |
Order as accessories |
Integrated |
||
Certification approval |
UL, CSA, IEC/EN (TÜV) |
UL, CSA, -UTU model by |
UL, CSA, VDE (reinforce |
UL, CSA, EN (TÜV certification) |
Self detection function |
Not supported |
|||
Alarm output |
Not supported |
|||
Replaceable power cartridge/ module |
No |
Yes (power device |
No |
Item Model |
||
Appearance |
|
|
Phase available |
Single |
|
Maximum load voltage (AC/DC) |
100 to 240 VAC |
100 to 480 VAC |
Maximum current available |
20 A |
25 A, 35 A |
Firing method |
Zero crossover |
|
Signal input |
VDC logic signal |
|
Soft-start function |
Not supported |
|
Duty setting |
Not supported |
Supported |
Built-in current transformer |
Built-in |
|
Support external CT |
Yes |
|
Communication option |
Not supported |
|
Type of mounting |
Screw type |
|
Heat sink option |
Integrated |
|
Certification approval |
EC, UL, CSA |
UL, CSA, EN certification |
Self detection function |
SSR failure detection | SSR failure detection, heater failure detection |
Alarm output |
Supported | |
Replaceable power cartridge/ module |
No |
Item Model |
||
Appearance |
|
|
Phase available |
Single-phase |
Eight-phase with SSR |
Maximum load voltage (AC/DC) |
100 to 240 VAC |
100 to 480 VAC |
Maximum current available |
20 A, 45 A, 60 A |
Define on SSR selection |
Firing method |
Phase angle / optimum cycle |
Control up to 8 SSRs |
Signal input |
4 to 20 mA VDC logic signal |
RS-485 Compoway/F |
Soft-start function |
Supported |
|
Duty setting |
Supported |
Not supported |
Built-in current transformer |
Yes (current-constant model) |
No |
Support external CT |
No |
Yes |
Communication option |
RS-485 |
RS-485 Compoway/F |
Type of mounting |
Screw mounting |
Screw or DIN rail mounting |
Heat sink option |
Integrated |
-- |
Certification approval |
CE and UL pending |
CE Mark, TÜV, UL, CSA |
Self detection function |
SSR failure detection, heater failure detection |
|
Alarm output |
Supported |
|
Replaceable power cartridge/ module |
--- |
--- |