Page top

page-top

Omron uses cookies to improve your experience on this website. By continuing to use the website, you hereby agree to our Privacy and Cookie Policy

Lead Contents

Counters: Voltage Values

FAQ No. FAQ00891

Primary Contents

What are the voltage values when the input terminals used for an NPN open-collector input are OFF and the current values when the input terminals are ON for the H7BR, H7HP, and H7EC Counters?

Answer


The following currents and voltages can be switched.

H7BR: 5 V, 2 mA


H7HP: 5 V, 2 mA


H7EC: 3 V, 20 μA