22.5-mm-width Timers
last update: January 10, 2014
Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min | 10 to
120 min |
1 to 12 h | 10 to 120 h | 100 to
1,200 h |
Scale numbers | 12 |
Power supply voltage *1 | 24 to 240 VAC/DC, 50/60 Hz *2
12 VDC *2 |
|
---|---|---|
Allowable voltage fluctuation range | 24 to 240 VAC/DC: 85% to 110% of rated voltage
12 VDC: 90% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.1 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption *4 | H3DKZ-A1 | At 240 VAC: 6.6 VA max. |
H3DKZ-A2 | At 240 VAC: 4.5 VA max. | |
Control output | Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC
with resistive load |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. * | |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts:
2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts of different polarity: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Static immunity | Malfunction: 4 kV, Destruction: 8 kV | |
Vibration
resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock
resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life
expectancy |
Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
EMC | (EMI) EN61812-1
Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 120 g |
* Actual value.
Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min | 10 to
120 min |
1 to 12 h | 10 to 120 h | 100 to
1,200 h |
Scale numbers | 12 |
Power supply voltage *1 | 24 to 240 VAC/DC, 50/60 Hz *2
12 VDC *2 |
|
---|---|---|
Allowable voltage fluctuation range | 24 to 240 VAC/DC: 85% to 110% of rated voltage
12 VDC: 90% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.1 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption | H3DKZ-F | At 240 VAC: 4.5VA max. *4 |
H3DKZ-FA | At 12 VDC: 0.6 W max. | |
Control output | Contact output (SPDT): 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at
24 VDC with resistive load *3, *4 |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS ±0.05 s max. * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. * | |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts:
2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Vibration
resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock
resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life
expectancy |
Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) | |
EMC | (EMI) EN61812-1
Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 110 g |
* Actual value.
Time range setting | t1x1 | t1x10 |
---|---|---|
Star set time (t1) range | 1 to 12 s | 10 to 120 s |
Star-Delta transfer time (t2) | Select from 0.05, 0.1, 0.25, or 0.5 s. |
---|
H3DKZ-G | H3DKZ-GE | |
---|---|---|
Power supply voltage *1 | 24 to 240 VAC/DC, 50/60 Hz *2 | 240 to 440 VAC (50/60 Hz) |
Allowable voltage fluctuation
range |
24 to 240 VAC/DC: 85% to 110% of rated voltage
240 to 440 VAC: 80% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.5 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption | At 240 VAC: 6.6 VA max. *4 | At 440 VAC: 34 VA max. |
Control output | Contact output (Time-limit output: relay, Star
output: SPDT, Delta output: SPDT): 5 A at 250 VAC with resistive load (cosφ = 1) 5 A at 24 VDC with resistive load *4, *5 |
I th 2 A
AC-15 120 VAC: 1.5 A AC-15 240 VAC: 1 A AC-15 440 VAC: 0.3 A |
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
H3DKZ-G | H3DKZ-GE | ||
---|---|---|---|
Accuracy of operating time | ±1% of FS max. | ||
Setting error | ±5% of FS ±0.05 s max. *1 | ||
Transfer time | Total error ± (25% of transfer time + 5 ms) max. *1 | ||
Influence of voltage | ±2% of FS max. *1 | ||
Influence of temperature | ±5% of FS max. *1 | ||
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts:
2,000 VAC 50/60 Hz for 1 min. *2 Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts of different polarity: 2,000 VAC 50/60 Hz for 1 min. *2 Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
||
Vibration
resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions | |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | ||
Shock
resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions | |
Malfunction | 100 m/s2 3 times each in 6 directions | ||
Life
expectancy |
Mechanical | 10 million operations min. (under no load
at 1,800 operations/h) |
10 million operations min. (under no load
at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC,
resistive load at 360 operations/h) |
100,000 operations min. (0.3 A at 440 VAC,
resistive load at 1,800 operations/h) |
|
EMC | (EMI) EN61812-1
Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 (EMS) EN61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
||
Degree of protection | IP30 (Terminal block: IP20) | ||
Weight | Approx. 120 g |
*1. Actual value.
*2. The dielectric strength of the H3DKZ-GE (240 to 440 VAC) is 2,500 VAC 50/60 Hz.
L Series | ||
---|---|---|
Time range setting | x1 | x10 |
Set time range | 1 to 12 s | 10 to 120 s |
Power ON time | 0.3 s min. | |
Scale numbers | 12 |
Supply voltage | 100 to 120 VAC, 50/60 Hz
200 to 240 VAC, 50/60 Hz |
|
---|---|---|
Allowable voltage fluctuation range | 85% to 110% of rated voltage | |
Power consumption | H3DKZ-HCL | At 120 VAC: 11.7 VA max. |
H3DKZ-HDL | At 240 VAC: 29.5 VA max. | |
Control output | Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC
with resistive load |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |
* The control output ratings are for one H3DKZ operating alone.
Accuracy of operating time | ±1% of FS max. | |
---|---|---|
Setting error | ±5% of FS * | |
Influence of voltage | ±2% of FS max. * | |
Influence of temperature | ±5% of FS max. (±2% ±10 ms max. at 1.2-s range) * | |
Dielectric strength | Between current-carrying metal parts and exposed non-current-carrying metal parts:
2,000 VAC 50/60 Hz for 1 min. Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min. Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min. |
|
Vibration
resistance |
Destruction | 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions |
Malfunction | 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions | |
Shock
resistance |
Destruction | 1,000 m/s2 3 times each in 6 directions |
Malfunction | 100 m/s2 3 times each in 6 directions | |
Life
expectancy |
Mechanical | 10 million operations min. (under no load at 1,200 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) | |
EMC | (EMI) EN 61812-1
Radiated Emissions: EN 55011 class B Emission AC Mains: EN 55011 class B Harmonic Current: EN 61000-3-2 Voltage Fluctuations and Flicker: EN 61000-3-3 (EMS) EN 61812-1 ESD Immunity: EN 61000-4-2: 6 kV contact discharge, 8 kV air discharge Radiated Radio-Frequency Electromagnetic Field Immunity (AM Radio Waves): EN 61000-4-3: 10 V/m (80 MHz to 1 GHz) Burst Immunity: EN 61000-4-4: 2 kV power line, 1 kV I/O signal line Surge Immunity: EN 61000-4-5: 2 kV common mode, 1 kV differential mode |
|
Degree of protection | IP30 (Terminal block: IP20) | |
Weight | Approx. 120 g |
* Actual value.
last update: January 10, 2014