Water Leak Detector
last update: April 1, 2022
61F-WL-CP[]-NRA | |
---|---|
Supply voltage/frequency | 100 VAC - 240 VAC 50/60 Hz |
Operating voltage range | 85% to 110% of rated voltage |
Operating frequency range | ±5 Hz of the rated frequency |
Power consumption | 3.2 VA max. |
Contact ratings | 3 A at 250 VAC (Resistive load (cosφ = 1))
1 A at 250 VAC (Inductive load (cosφ = 0.4)) Minimum applicable load 5 VDC, 1 mA (reference value) |
Ambient temperature | -10 to +55°C |
Ambient humidity | 25 to 85% RH |
Ambient storage temperature | -10 to +55°C |
Ambient storage humidity | 25 to 85% RH |
Weight | Approx. 100 g |
Accessories | PFC-N8 |
61F-WL-CP[]-NRA | |
---|---|
Operation resistance | Variable (0 to 50 kΩ) |
Operation resistance error | Scale 0: 0 to 10 kΩ *1
Scale 50: 50 ±10 kΩ |
Release resistance | Operation resistance + 50 kΩ or less |
Interelectrode voltage | 5 VAC |
Response time | Operate: 80 ms max.
Release: 160 ms max. |
Startup lock time | 3 s after turning on the power supply (The LED blinks during the startup lock time) |
Insulation resistance *2 | 100 MΩ min. (at 500 VDC) |
Dielectric strength *2 | 2000 VAC, 50/60 Hz for 1 min. |
Life expectancy | Electrical: 100,000 operations min.
Mechanical: 5,000,000 operations min. |
Approved standards | UL61010-1, CAN/CSA C22.2 No.61010-1
CE, RCM EN61010-1, EN61326-1 Industrial electromagnetic environment |
last update: April 1, 2022