Slim I/O Relay
last update: November 18, 2024
Rated input
voltage |
Rated current | Must
operate voltage |
Must
release voltage |
Power consumption | Maximum
allowable voltage |
|||
---|---|---|---|---|---|---|---|---|
AC | DC | Percentage of the
rated voltage |
AC (VA) | DC (mW) | Percentage
of the rated voltage |
|||
50 Hz | 60 Hz | |||||||
12 VDC | - | - | 27.9 mA | 80% max.* | 10% min. | - | Approx. 300 mW | 110% |
24 VDC | - | - | 13.5 mA | - | Approx. 300 mW | |||
24 VAC/VDC | 13.7 mA | 14.9 mA | 12.6 mA | Approx. 0.4 VA | Approx. 300 mW | |||
48 VAC/VDC | 5.9 mA | 6.4 mA | 5.4 mA | Approx. 0.3 VA | Approx. 250 mW | |||
100 VAC | 6.8 mA | 7.1 mA | - | Approx. 0.7 VA | - | |||
110 VAC | 6.1 mA | 6.4 mA | - | Approx. 0.7 VA | - | |||
200 VAC | 6.1 mA | 7.3 mA | - | Approx. 1.5 VA | - | |||
230 VAC | 6.8 mA | 8.2 mA | - | Approx. 1.9 VA | - |
Note: The operating characteristics are measured at ambient temperature of 23°C.
The rated current tolerances are as follows. AC rating: +15%/-20%, DC rating: ±10%
* Operating voltage will be, for mounting in the upside down direction, 85% max.
(Upside down: Direction in which the mechanical indicator faces down)
Item | Standard
(G2RV-ST700, 500, 701, 501) |
For microloads
(G2RV-ST700-AP, 500-AP) *2 |
|
---|---|---|---|
Contact configuration | SPDT | ||
Load | Resistive load
(cosφ=1) |
Inductive load
(cosφ=0.4, L/R=7ms) |
Resistive load
(cosφ=1) |
Rated load | 6 A at 250 VAC
6 A at 30 VDC |
2.5 A at 250 VAC
2 A at 30 VDC |
50 mA at 30 VAC
50 mA at 36 VDC |
Rated carry current *3 | 6 A | 50 mA | |
Maximum switching voltage | 440 VAC, 125 VDC | 30 VAC, 36 VDC | |
Maximum switching current | 6 A | 50 mA | |
Maximum switching power | 1,500 VA
180 W |
500 VA
60 W |
- |
Failure rate P value
(reference value) *1 |
10 mA at 5 VDC | 1 mA at 100 mVDC |
*1. P level: λ60=0.1×10-6/times
This value is the value in switching frequency 120 operations/min.
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.
*3. Please energize under 32A total when use short bar connection.
Item | Standard
(G2RV-ST700, 500, 701, 501) |
For microloads
(G2RV-ST700-AP, 500-AP) |
|
---|---|---|---|
Contact resistance * | 100 mΩ max. | ||
Operate time * | 20 ms max. | ||
Release time * | AC, AC/DC: 40 ms max.
DC: 20 ms max. |
||
Maximum operating frequency | Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load) |
||
Insulation resistance | 1,000 MΩ min. (at 500 VDC) | ||
Dielectric strength | Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min |
||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) |
||
Shock resistance | Destruction: 1,000 m/s2
Malfunction: Energized 200m/s2, Non-energized 100m/s2 |
||
Endurance * | Mechanical | 5,000,000 operations min. | |
Electrical | NO contact: 70,000 operations min.
NC contact: 50,000 operations min. |
5,000,000 operations min. | |
Ambient operating
temperature |
Operating: -40 to +55°C (with no icing or condensation) | ||
Ambient operating
humidity |
Operating: 5 to 85% RH | ||
Weight | Approx. 30 g | ||
Type of interruption | Micro-disconnection | ||
Type of insulation | Basic isolation: Coil-Contact, Live parts-Ground | ||
Pollution degree | 2 | ||
Impulse withstand
voltage |
4.0 kV | ||
Test procedure | A (Group mounting) | ||
Categories of
environmental protection |
RT 1 | ||
Degree of protection by
enclosure according to IEC 60529 |
IP20 | ||
Contact material | Ag alloy | Ag alloy + Au plating |
Note: Above values are initial values.
* Value is at ambient temperature of 23°C.
Model | Contact form | Operation coil ratings | Contact ratings | Operations |
---|---|---|---|---|
G2RV-ST series | SPDT | 12 to 48 VDC
24 to 230 VAC |
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load) 2 A at 400 VAC (Resistive load)* |
6,000 |
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12) or 4psc of isolation plate (P2RV-P3.1T).
Model | Contact form | Operation coil ratings | Contact ratings | Operations |
---|---|---|---|---|
G2RV-ST series | SPDT | 12, 24 VDC
24, 48 VAC/VDC 100, 110, 200, 230 VAC |
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load) 2 A at 400 VAC (Resistive load)* |
50,000
50,000 6,000 |
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12) or 4psc of isolation plate (P2RV-P3.1T).
Model | No. of poles | Operation coil ratings | Contact ratings |
---|---|---|---|
G2RV-ST500
G2RV-ST700 |
1c | 12, 24 VDC
24, 48 VAC/VDC 100, 110, 200, 230 VAC |
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4) 6 A at 30 VDC (Resistive load) 2 A at 30 VDC (L/R=7 ms) |
G2RV-ST501
G2RV-ST701 |
1c | 12, 24 VDC
24 VAC/VDC |
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4) 6 A at 30 VDC (Resistive load) 2 A at 30 VDC (L/R=7 ms) |
G2RV-ST500-AP
G2RV-ST700-AP |
1c | 12, 24 VDC
24, 48 VAC/VDC 100, 110, 200, 230 VAC |
0.05 A at 30 VAC (Resistive load)
0.05 A at 36 VDC (Resistive load) |
Rated insulation voltage | 30 VAC/DC * | |
---|---|---|
Rated current | 0.5 A/poles, 2 A/unit | |
Ambient operating temperature | -40 to 55°C | |
Vibration resistance | Destruction | 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) |
Malfunction | 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) | |
Shock resistance | Destruction | 300 m/s2 |
Malfunction | 100 m/s2 |
* DC voltage is limited to 30 V.
last update: November 18, 2024